Groline Nutrient Dosing System with HI30033 EC probe (HI981413-00)
  • altimage
  • altimage
  • altimage
  • altimage

share thisGroline Nutrient Dosing System with HI30033 EC probe (HI981413-00)

Price:$459.99
  • $459.99


Product Description

The HI981413 Nutrient Dosing System is engineered for maintaining the concentration of fertilizer in the nutrient solution used in hydroponics and irrigation water. The nutrient concentration in the water used for irrigation is critical for the successful propagation and growth of plants. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.

Available in multiple configurations for easily integration into your setup.

Programmable alarm system and multicolored LCD display.

Perfect for small hydroponics systems.

GroLine Nutrient Dosing System

Peristaltic Dosing Pump

The powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.

Automatic Proportional Pump Control

The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point.

Adjustable Flow Rate

The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.

Acid Tank Level/Flow Switch Input

A connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

Multicolored LCD Display

A multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.

Quick Connect Probe Input

The Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.

GroLine EC/Temperature Probe

The HI981413 uses the HI30033 amplified probe that incorporates both EC (TDS) and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.

PVDF body

1/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell

Specification Name

Detail

SKU

HI981413

Temperature Range

-5.0 to 105°C (23.0 to 221.0°F)

Temperature Resolution

0.1°C (0.1°F)

Temperature Accuracy (@25°C/77°F)

±0.5°C (±0.9°F)

EC Range

0.00 to 10.00 mS/cm

EC Resolution

0.01 mS/cm

EC Accuracy (@25°C/77°F)

±2% F.S.

TDS Range

0 to 4500 ppm (TDS conversion factor 0.45)

0 to 9900 ppm (TDS conversion factor 0.99)

TDS Resolution

1 ppm

TDS Accuracy (@25°C/77°F)

±2% F.S.

TDS Conversion Factor

TDS conversion factor selectable from 0.45 to 0.99

Temperature Compensation

automatic

Temperature Coefficient

β can be set from 0%/°C to 2.4%/°C; default is 1.9%/°C

Calibration

EC: user calibration: automatic, one-point with standard solution (1.413 or 5.000 mS/cm)

Process calibration: single point, adjustable (±0.50 mS/cm around measured value)

TDS: through EC calibration

Pump Control

selectable flow rate (0.5 to 3.5 L / hour; 0.13 to 0.92 G/hour)

manual control for pump priming

Alarms

high and low with enable / disable option

triggered after 5 sec. if controller records a set of consecutive readings over / under threshold values level with enable / disable option

overtime protection (1 to 180 min. or off)

intuitive alarm system using red, light green, and green color-coded backlight

External Event Input

input for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch - galvanically isolated

Alarm Relay Output

SPDT 2.5A / 230 VAC

Power Supply

100—240 VAC, 50/60 Hz

Power Consumption

15 VA

Casing

wall mounted, built-in pump, IP65 rated

Environment

0-50°C (32-122°F), max. 95% RH non-condensing

Dimensions

90 x 142 x 80 mm (3.5 x 5.6 x 1.8”)

Weight

910 g (32 oz.)

Ordering Information

HI981413-00 is supplied with HI30033 EC/TDS/temperature probe, conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.

 

Recommended Probe

HI30033 EC/TDS/Temperature probe with quick connect DIN connector - galvanically isolated