Hanna HI70007G pH 7.01 Calibration Buffer - GroLine Sachets (25 x 20mL)
  • altimage
  • altimage

share thisHanna HI70007G pH 7.01 Calibration Buffer - GroLine Sachets (25 x 20mL)

Price:$49.99
  • $49.99


Product Description

Hanna HI70007G pH 7.01 Calibration Buffer - Professional GroLine Sachets

The Hanna HI70007G pH 7.01 Calibration Buffer is a high-precision, NIST-traceable calibration standard designed specifically for hydroponics, aquaponics, greenhouses, and water quality testing applications. Each box contains 25 individually sealed 20mL sachets that deliver fresh, uncontaminated pH 7.01 buffer solution every time, ensuring optimal meter accuracy and reliable measurements.

Key Features

NIST Traceable: Accurate to ±0.02 pH @ 25°C, traceable to NIST Standard Reference Materials

Certificate of Analysis: Each lot supplied with complete documentation for quality assurance

25 Individual Sachets: Pre-measured 20mL single-use sachets ensure fresh solution every calibration

Light-Blocking Foil: UV-resistant packaging prevents degradation and extends shelf life

5-Year Shelf Life: Unopened sachets remain stable for up to 5 years from manufacture

Lot Number & Expiration: Each sachet stamped with full traceability information

ISO 3696/BS3978 Certified: Manufactured to international quality standards

Dye-Free Formula: Won't stain or contaminate pH electrode reference cells

GroLine Optimized: Perfect for use with GroLine testers and portable meters

Why pH 7.01 Buffer?

pH 7.01 is the neutral point calibration standard used in multi-point pH calibration procedures. When calibrating pH meters, the 7.01 buffer serves as the central reference point, with acidic (pH 4.01) and alkaline (pH 10.01) buffers used to establish the full calibration curve. For single-point calibration, pH 7.01 provides the most accurate reference for samples near neutral pH, making it essential for hydroponics, aquariums, and general water quality testing.

Professional-Grade Manufacturing

ISO 3696/BS3978 Compliance

The HI70007G is manufactured in accordance with ISO 3696 and BS3978 international standards for analytical-grade water and reagents. This ensures consistent quality, accuracy, and reliability across every batch. The production process includes:

High-Purity Salts: Pharmaceutical-grade reagents for precise pH values

Deionized Water: Ultra-pure water free from contaminants that could affect pH

Certified Balances: Weight-checked analytical balances for exact formulation

Class A Glassware: Laboratory-grade glassware for accurate measurements

Temperature Control: Climate-controlled manufacturing environment

Certified Thermometers: Traceable temperature monitoring throughout production

NIST Traceability

Every lot of HI70007G is verified against NIST Standard Reference Materials (SRMs), ensuring accuracy to ±0.02 pH at 25°C. This traceability is essential for laboratory quality control, regulatory compliance, and applications requiring documented calibration standards. The Certificate of Analysis provided with each lot includes the specific NIST SRMs used for verification.

Dye-Free Formulation

Unlike some colored buffer solutions that can stain or contaminate the reference junction of pH electrodes, the HI70007G is completely dye-free. This prevents reference cell contamination that can cause drift, slow response times, and premature electrode failure. The clear solution also makes it easy to verify cleanliness and detect any contamination.

Single-Use Sachet Advantages

Always Fresh, Never Contaminated

Each 20mL sachet is hermetically sealed at the time of manufacture, preserving the buffer solution in pristine condition until you're ready to use it. Unlike bottled buffers that can become contaminated after opening or absorb CO₂ from the air (affecting pH), every sachet provides a fresh, uncontaminated calibration standard. After calibration, simply discard the used solution—no storage concerns, no degradation worries.

Light-Blocking Foil Packaging

UV light can degrade buffer solutions over time, affecting their accuracy. The HI70007G sachets feature light-tight foil packaging that completely blocks UV radiation, preserving the buffer's integrity from manufacturing through your calibration procedure. This ensures consistent accuracy across the entire 5-year shelf life.

Full Traceability

Every sachet is stamped with a lot number and expiration date, providing complete traceability for quality control and regulatory compliance. This is essential for laboratory environments, commercial operations, and any application requiring documented calibration procedures. The lot number corresponds to the Certificate of Analysis, allowing you to verify the exact specifications of your buffer solution.

Portable & Field-Ready

The compact, lightweight sachets are perfect for on-the-go testing. They fit easily into your pocket, carrying case, or field testing kit, making them ideal for greenhouse operations, aquaculture facilities, environmental monitoring, and any application requiring portable calibration capability.

Technical Specifications

Specification

Detail

Product Code

HI70007G

pH Value

7.01 @ 25°C

Accuracy

±0.02 pH @ 25°C

Traceability

NIST Standard Reference Materials (SRMs)

Quantity

25 sachets per box

Volume per Sachet

20 mL

Total Volume

500 mL (25 x 20 mL)

Packaging

Light-blocking foil sachets

Color

Clear (dye-free)

Usage

Single-use (discard after calibration)

Shelf Life

Up to 5 years (unopened)

Manufacturing Standard

ISO 3696/BS3978

Certificate of Analysis

Included with each lot

Weight

1.5 lb (680 g)

Barcode

606795356232

Country of Origin

Romania

Manufacturer

Hanna Instruments

Certificate of Analysis

Each lot of HI70007G is supplied with a comprehensive Certificate of Analysis that includes:

Product Code: HI70007G identification

Lot Number: Unique batch identifier

Mean Lot Value: Actual measured pH value for the specific lot

NIST SRMs Used: Specific Standard Reference Materials used for verification

Manufacturing Date: Production date for traceability

Expiration Date: Guaranteed shelf life information

This documentation is essential for laboratory quality systems, regulatory compliance (GLP, ISO 17025), and audit trails.

Compatible Meters & Applications

GroLine Meters

The HI70007G is specifically designed for use with Hanna's GroLine series of pH testers and portable meters, including:

GroLine pH testers (HI98118, HI98127, HI98128)

GroLine combination meters (HI9814, HI98129, HI98130)

GroLine portable pH meters

All Hanna pH meters requiring pH 7.01 calibration

Applications

Hydroponics: Calibrate nutrient solution pH meters for optimal plant nutrition

Aquaponics: Maintain accurate water quality monitoring equipment

Aquariums: Ensure precise pH measurement for fish and coral health

Greenhouses: Calibrate irrigation and fertigation system pH meters

Pools & Spas: Verify water chemistry testing equipment accuracy

Laboratories: Quality control and routine meter calibration with full traceability

Environmental Testing: Field calibration for water quality monitoring

Agriculture: Soil solution and irrigation water pH testing

Food & Beverage: Process water and product quality control

Education: Science labs and research facilities

Wastewater Treatment: Effluent monitoring and process control

Calibration Procedure

Prepare Meter: Turn on your pH meter and enter calibration mode

Rinse Electrode: Rinse the pH electrode with distilled or deionized water and gently blot dry

Open Sachet: Tear open one fresh HI70007G sachet

Pour Solution: Pour the entire contents into a clean calibration container or beaker

Immerse Electrode: Submerge the pH electrode in the buffer solution, ensuring the glass bulb and reference junction are fully covered

Stir Gently: Gently swirl the electrode to remove air bubbles and ensure contact with fresh solution

Wait for Stability: Allow the reading to stabilize (typically 30-60 seconds)

Confirm Calibration: Accept the calibration point when the meter indicates stability at pH 7.01

Rinse & Continue: Rinse the electrode with distilled water before proceeding to additional calibration points (pH 4.01, pH 10.01) if performing multi-point calibration

Discard Solution: Dispose of used buffer solution—never reuse

Multi-Point Calibration

For maximum accuracy across a wide pH range, perform a 3-point calibration using:

pH 4.01 Buffer (HI70004G): Acidic calibration point

pH 7.01 Buffer (HI70007G): Neutral calibration point

pH 10.01 Buffer (HI70010G): Alkaline calibration point

This establishes a complete calibration curve for accurate measurements from acidic to alkaline samples.

Calibration Best Practices

Calibrate Regularly: Calibrate before each use or at minimum weekly for critical applications

Use Fresh Solution: Always use a new sachet—never reuse buffer solution

Check Expiration Date: Verify the expiration date on each sachet before use

Clean Container: Use a clean, uncontaminated calibration container for each calibration

Rinse Thoroughly: Always rinse the electrode with distilled water between buffer solutions

Temperature Matters: Allow buffer and electrode to equilibrate to the same temperature

Document Calibration: Record lot number, date, and calibration results for quality assurance

Replace Electrodes: If calibration is difficult or unstable, the electrode may need replacement

Storage & Handling

Store sachets in a cool, dry place away from direct sunlight

Keep sachets sealed until ready to use

Avoid exposure to extreme temperatures

Do not freeze

Check expiration date before use

Store in original packaging for maximum shelf life

Unopened sachets remain stable for up to 5 years

Why Choose HI70007G?

The HI70007G represents the gold standard in pH calibration buffers for hydroponics, aquaponics, and water quality testing. The combination of NIST traceability, ISO-certified manufacturing, and single-use sachet convenience ensures you're calibrating with the most accurate, reliable buffer solution available. Whether you're managing a commercial greenhouse operation, maintaining aquarium water quality, or conducting laboratory water analysis, the HI70007G delivers professional-grade accuracy with unmatched convenience.

The dye-free formulation protects your expensive pH electrodes from reference cell contamination, while the light-blocking foil packaging ensures each sachet remains accurate for up to 5 years. With 25 sachets per box, you have enough calibration solution for regular maintenance over several months, and the Certificate of Analysis provides the documentation required for quality control and regulatory compliance.

Complete Calibration Kit

For comprehensive pH meter calibration, consider pairing the HI70007G with:

HI70004G: pH 4.01 buffer sachets (acidic calibration point)

HI70010G: pH 10.01 buffer sachets (alkaline calibration point)

HI70300: pH electrode storage solution

HI7061: pH electrode cleaning solution

Package Contents

25 individually sealed 20mL sachets of pH 7.01 buffer solution

Each sachet stamped with lot number and expiration date

Certificate of Analysis (included with lot)

Manufacturer: Hanna Instruments (GroLine Series)

SKU: HI70007G

Barcode: 606795356232

Origin: Romania

For best results, use with genuine Hanna pH meters and electrodes. Calibrate regularly according to your meter's user manual and your application requirements.