Product Description
Our Marine Algae and Nutrient Management Kit is ideal for testing saltwater aquariums, reef tanks, and other marine and aquaculture applications.
Easily monitor nutrients, prevent algae, and maintain reef balance. This kit arrives with everything you need to keep both saltwater parameters in check to ensure a healthy and thriving environment. Stop guessing with color charts. Get fast, accurate digital readouts in the palm of your hand with these Checkers®HC.
Easy-to-read, instant digital results
Compact and portable
Simple one-button designs and straightforward steps
Start testing right out of the box and control algae growth in aquariums
Regulating phosphate and nitrate is essential. Algae can grow rapidly and become problematic when these parameters are too high whereas levels that are too low will starve corals and disrupt biological processes. Enjoy hassle-free testing and incorporate our Marine Algae and Nutrient Management Kit as part of your reef tank maintenance routine.
Features
Saltwater compatible
Checkers®HC are dedicated to a single parameter
A great alternative to chemical test kits
Digital readouts appear on large LCD screens
Pocket-sized, lightweight
Easy-to-use, convenient
Requires little maintenance
Comes as a complete algae and nutrient management kit
Be ready to test right out of the box with all necessary reagents, accessories, and batteries
Auto shut-off conserves battery energy
Phosphate range: 0.00 to 0.90 ppm
Nitrate range: 0.0 to 75.0 ppm (as NO3-)
Specification
Detail
Phosphate Ultra Low Range (ULR)
0.00 to 0.90 ppm
Phosphate ULR Resolution
0.01 ppm
Nitrate High Range (HR)
0.0 to 75.0 ppm (as NO3)
Nitrate HR Resolution
0.1 ppm
Phosphate ULR Accuracy @ 25°C (77°F)
±0.02 ppm ±5% of reading
Nitrate HR Accuracy @ 25°C (77°F)
±2.0 ppm ±5% of reading
Light Source
Light Emitting Diode @ 525 nm
Light Detector
Silicon photocell
Phosphate ULR Method
Adaptation of Standard Methods for the Examination of Water & Wastewater, 20th Edition, Ascorbic Acid Method.
The reaction between phosphate and the reagent causes a blue tint in the sample.
Nitrate HR Method
Zinc reduction method. The reaction between nitrate and the reagent causes a pink tint in the sample. This checker has been developed to work with seawater samples.
Battery Type
1.5V AAA Alkaline
Phosphate ULR Auto Shut-Off
After 7 minutes of non-use and 2 minutes after reading
Nitrate HR Auto Shut-Off
After 10 minutes of non-use
Environment
0 to 50 °C (32 to 122 °F); max. RH 95% non-condensing
Dimensions
86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5")
Weight
64 g (2.3 oz)
Nitrate HR Interferences
Nitrite
Reagent Sets
HI774-25 (25 tests for Phosphate ULR) / HI782-25 (25 tests for Nitrate HR)
Calibration Check
HI774-11 for Phosphate ULR / HI782-11 for Nitrate HR
Warranty
1 year
What's included
Marine Phosphate Ultra Low Range Checker®HC (HI774) supplied with protective case
Marine Phosphate Ultra Low Range reagents for 35 tests
Marine Nitrate High Range Checker®HC (HI782) supplied with protective case
Marine Nitrate High Range reagents for 35 tests
Sample cuvette and cap (4 pcs.)
3 mL Pasteur pipette (1 pc.)
1.5V AAA Alkaline batteries (2 pcs.)
Instruction manuals